DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1417
TDM-CLK (TDM Bus Clock) 
10
TDM Bus Clock Circuit Status Inquiry Test (#148)
The TDM Bus Clock circuitry is checked for sanity. Any problems that are found 
are reported via error codes
Table 10-431.
TEST #148 TDM Bus Clock Circuit Status Inquiry Test 
Error 
Code
Test 
Result
Description/ Recommendation
None 
1001
ABORT
The system could not allocate the necessary resources for the test.
1. Wait 1 minute, and retry the test.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1
FAIL
This error means the Tone-Clock circuit pack framing verification firmware 
reports an error in the clock synchronization signal coming into this Port 
Network.
1. If the Tone-Clock circuit pack reporting the problem is a master clock, 
then the system synchronization reference is providing a bad timing 
source. Refer to SYNC (Synchronization) or STRAT-3 (Stratum 3 Clock) 
Maintenance documentation to change the system synchronization 
reference.
2. If the Tone-Clock circuit pack is a slave clock, then the EI to which it is 
listening is providing a bad timing source. Follow the diagnostic 
procedures specified for TDM-CLK Error Code 2305.
3. If no problem can be found with the incoming synchronization signal, 
replace the Tone-Clock circuit pack. See 
How to Replace the 
Tone-Clock Circuit Pack in the TONE-BD section.
2
FAIL
This error indicates that Tone-Clock circuit pack has inaccurately detected 
loss of signal on the incoming synchronization timing source.
4
or
8
FAIL
The local oscillator on the Tone-Clock circuit pack has failed.
16
or
32
FAIL
The circuitry on the Tone-Clock circuit pack used to detect synchronization 
timing errors has failed.
1. Errors 2, 4, 8, 16, and 32 indicate that there is poor synchronization 
between port networks and external facilities. It may be noticeable to 
the customer in the form of errors in data communications. The 
Tone-Clock circuit pack is defective. See 
How to Replace the 
Tone-Clock Circuit Pack in the TONE-BD section.
Continued on next page