Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1455
TIE-TRK (Tie Trunk) 
10
a. ATMS test are not part of either sequence. They are run either on demand 
with the 
test analog-testcall
 command or via the ATMS schedule.
NPE Crosstalk Test (#6)
One or more NPE reside on each circuit pack with a TDM Bus interface. The NPE 
controls port connectivity and gain, and provides conferencing functions on a 
per port basis. The NPE Crosstalk Test verifies that this port’s NPE channel talks 
on the selected time slot and never crosses over to time slots reserved for other 
connections. If the NPE is not working correctly, one-way and noisy connections 
may be observed. This test is usually only part of a port’s Long Test Sequence 
and takes 20 to 30 seconds to complete.
Table 10-442.
TEST #6 NPE Crosstalk Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to 
run this test.
1. Retry the command at one minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources required to run this test are not 
available. The trunk may be busy with a valid call. Use 
the 
display trunk xx
 command to determine the trunk 
group/member number of the port. Use the 
status trunk
 
command to determine the service state of the port. If 
the service state indicates that the port is in use, the port 
is unavailable for certain tests. (Refer to "Status 
Commands" section in 
 for a full 
description of all possible states.) You must wait until the 
port is idle before retesting.
1. If the port status is active, but the port is not in use 
(no connected ports), check the Error Log for Error 
Type 1025 (see Error Log table for description of this 
error and required actions). The port may be locked 
up.
2. If the port status is idle, retry the command at 
one-minute intervals a maximum of five times.
3. If the test continues to abort, escalate the problem.
Continued on next page