Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1464
TIE-TRK (Tie Trunk) 
10
Audit Update Test (#36)
This test sends updates of the Tie Trunk port translation for all ports on the circuit 
pack that have been translated. The update is non-disruptive and guards against 
possible corruption of translation data contained on the board. No response 
message is expected from the circuit pack once it receives translation updates. 
The port translation data for non-TN439 and non-TN497 circuit packs includes 
the following: Immediate, automatic, wink-start or delay dial trunk, rotary or DTMF 
senderization in or out, disconnect timing from 10 to 2550ms in 10ms increments, 
and DMTF time slot. (Continuous-seize-ack is also included for the TN2140 
[G3iV2-386] circuit pack.) The port translation data for the TN439 circuit pack 
includes the following: Immediate or wink-start trunk, rotary or DTMF 
senderization in or out, disconnect timing from 10 to 2550ms in 10ms increments, 
and DMTF time slot.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board).
1. Check to ensure that the board translations are 
correct. Translate the board, if necessary.
2. Issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board
 command. This should 
re-establish the linkage between the internal ID and 
the port.
Table 10-443.
TEST #33 Loop Around and 
Conference Circuit Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page