Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-25
busyout pms-link 
8
Output
For the following output example, the command busyout packet-control 1A was 
entered.
Feature Interactions
In a duplicated system, an attempt to busyout the packet-control that resides in 
the standby processor complex will be disallowed.
When the packet-control in the active control complex is busied out, all 
connectivity across the Packet Bus will be severed. Thus, all ISDN-BRI 
point-to-point signaling links that have been established via the active 
packet-control will be torn down by the busyout packet-control command. The 
release packet-control command will reestablish all Packet Bus connectivity.
busyout pms-link
This command will busyout a specified property management system link.
Port
This field represents the Cabinet-Carrier in which the 
Packet-Control resides.
Maintenance Name
The type of maintenance object that is being busied out ( which in 
this case is always PKT-CTRL).
Alt. Name
This field is not used in this output display.
Result
An indicator as to whether the object was successfully busied out 
( "PASS," "ABORT," or "FAIL").
Error Code
A system-generated number that tells why the busyout failed or 
aborted. A detailed list of the codes is present in the 
"Busyout/Release Error Codes" section of this chapter.
 
 busyout packet-control 1A                          SPE A
 
                             COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
 
   1A       PKT-CTRL                     PASS
 Command successfully completed