Page 10-1511
TONE-PT (Tone Generator) 
10
Tone Generator Crosstalk Test (#90)
This test checks the ability of the Tone Generator to talk on a specific time slot. 
The tone generator is told to talk on a specific time slot. The other idle time slots 
are checked to make sure the Tone Generator put the tone on only the specified 
time slot.
2
FAIL
The system requires TN2182 tone-clocks to support the 
currently administered country-options tone generation 
parameters.
1. Check the administration on the system-parameters 
country-option form. Specifically, the Base Tone 
Generation Set on page 1 and any custom tone 
administration beginning on page 2.
2. Replace existing tone-clock circuit packs with 
TN2182s.
PASS
The tone generation facility has been successfully 
refreshed with its time-slot translation and system 
administration is consistent with this type of tone-clock.
1. Display the Hardware Error Log via the 
display 
errors
 command to make sure this circuit pack did 
not generate new errors.
2. If errors persist, follow normal escalation 
procedures.
Table 10-451.
TEST #41 Tone Generator Update/Audit Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page