Maintenance Commands and Trouble-Clearing Aids 
Page 8-29
busyout port 
8
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "busyout port," the following 
message will be displayed:
 Enter 7 character port number
Error Messages
If the format of the port location is incorrect, the following error message will be 
displayed:
 Port/Board invalid
If the EPN on which the port resides is unavailable, the following message will be 
displayed:
 EPN is not available
If the board on which the port resides is not administered, the following error 
message will be displayed:
 Port not assigned
If the board on which the port resides is part of the SCI link, the following error 
message will be displayed:
 Cannot busyout/release part of SCI link
If the port is translated within a Wideband Access Endpoint, the following error 
message will be displayed:
 Port within wideband access endpt; Use busyout access-endpoint <ext> instead
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
location
A "location" represents the physical position of the port to be 
busied out and is entered as "UUcSSpp" where "UU" represents 
the cabinet number (1-3), "c" represents the carrier, "SS" 
represents the slot position, and "pp" represents the circuit 
(port).
A "location" represents the physical position of the port to be 
marked and is entered as "PCSSpp" where P is the port network 
number (1 for PPN, 2 for EPN, and 3 for the second EPN); C is 
the carrier designation (for example, A, B, C, D, or E); and SS is 
the address of the slot in the carrier where the circuit pack is 
located (for example, 01, 02, ...etc.), and "pp" represents the 
circuit (port). A single digit cabinet (1 - 3) may be entered with 
or without a leading zero (0).