Maintenance Object Repair Procedures 
Page 10-1568
UDS1-BD (UDS1 Interface Circuit Pack) 
10
software restores all trunks or ports of the UDS1 Interface circuit pack to the 
service state before the Red alarm occurs.
Loss of Multiframe Alarm
If the UDS1 Interface circuit pack is administered using DMI-BOS signaling, the 
UDS1 Interface circuit pack raises a Loss of Multiframe Alarm (LMA) when it 
cannot interpret the incoming signaling bits to synchronize to the multiframe 
pattern received in the 24th channel. Once the UDS1 Interface circuit pack 
detects an LMA, the circuit pack will transmit a Remote Multiframe Alarm (RMA) 
to the remote DS1 endpoint. Maintenance software handles both Red alarm and 
LMA alarm(s) using the same mechanism.
Table 10-462.
TEST #140 Red Alarm Inquiry Test 
Error 
Code
Test 
Result
Description/ Recommendation
 
ABORT
Internal System Error
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.