Page 10-1587
UDS1-BD (UDS1 Interface Circuit Pack) 
10
Slip Alarm Inquiry Test (#144)
Slips occur when transmitter and receiver are not running at precisely the same 
clock rate. The UDS1 Interface circuit pack can detect both positive and 
negative slips on the DS1 facility. The Slip Alarm Inquiry Test is used to acquire 
the total number of slips that have occurred on a DS1 link.
When the UDS1 Interface circuit pack detects a slip condition, the circuit pack 
will increase the on-board slip counter by 1. A SLIP-COUNT message is 
spontaneously sent to the system software after the counter reaches a threshold 
(for example, 88). When the maintenance software receives the SLIP-COUNT 
message, the Slip Alarm Inquiry Test is initiated to query the slip counters on a 
UDS1 Interface circuit pack and total the slip counts in the maintenance 
software.
If the count of slips is over the threshold, a Minor alarm is raised against the 
UDS1 Interface circuit pack. All trunks or ports of the UDS1 Interface circuit pack 
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-465.
TEST #143 Minor Alarm Inquiry Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page