Maintenance Commands and Trouble-Clearing Aids 
Page 8-36
busyout spe-standby 
8
Synopsis
busyout spe-standby
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Examples
busyout spe-standby
Description
The busyout spe-standby command raises the Fault Severity Level of the 
Standby SPE (see reference 5) of the standby Switch Processing Element (SPE) 
by raising a Warning Off-board alarm against STBY-SPE. Because a Warning 
Off-board STBY-SPE alarm is defined to have the highest Fault Severity of all 
alarms the affect the health of an SPE (refer to the Reset System MUS), the 
chance that an SPE interchange will occur is diminished, but does not guarantee 
that an SPE interchange will not occur. Once the standby SPE is busied out, an 
SPE interchange will only occur if the standby SPE is hard selected via the SPE 
Select switches or the active SPE goes into SPE down mode. This command will 
also stop any activity currently executing on the standby SPE and will disable 
memory shadowing to the standby SPE. Periodic and scheduled testing 
will
 be 
prevented from starting on the standby SPE while it is busied out. The busyout 
state of the standby SPE and the STBY-SPE Warning alarm will be maintained 
across a reset system 1 (Warm restart) and a reset system 2 (Cold 2 restart) but 
will be removed after all other levels of restart.
Defaults
No defaults.
Parameters
None.
Help Messages
If the system technician presses 
HELP
 after entering "busyout spe-standby" the 
following message will be displayed:
 Entry is not required