Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1610
UDS1-BD (UDS1 Interface Circuit Pack) 
10
CPE Loopback Jack Test (#1212)
This test is destructive.
 
FAIL
UDS1 Interface circuit pack failed the CSU Repeater 
Loopback Test. 
1. Retry the 
test ds1-loop PCSS 
ds1/csu-loopback-tests
 command.
2. If the RLB test continues to fail, and the CSU 
Equipment Loopback Test (#1210) passed, then 
replace the CSU Module.
 
PASS
The RLB test executed successfully. The test pattern 
was transmitted and received successfully over the 
connection from the TN464F DS1 board to the far-edge 
of the 120A1 CSU Module.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-471.
TEST #1211 CSU Repeater Loopback Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page