Page 10-1626
UDS1-BD (UDS1 Interface Circuit Pack)
10
Inject Single Bit Error Test (#1215)
This test is destructive.
The Inject Single Bit Error Test will cause a single bit error to be sent within an
active framed 3-in-24 test pattern.
active framed 3-in-24 test pattern.
The test is highly destructive and can only be initiated by a system technician
demanded
demanded
test ds1-loop PCSS inject-single-bit-error
command. An attempt to
use this command will be rejected if none of the three long-duration DS1
loopback/span tests (CPE Loopback Jack Test, Far CSU Loopback Test,
One-Way Span Test) are active on a TN464F circuit pack.
loopback/span tests (CPE Loopback Jack Test, Far CSU Loopback Test,
One-Way Span Test) are active on a TN464F circuit pack.
All trunks or ports on the UDS1 Interface circuit pack must be busied out via the
system technician
system technician
busyout board
command before running the Inject Single Bit
Error Test.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Ensure that the board translations are correct.
Execute the
add ds1 PCSS
command to administer
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly,
check the error log to determine whether the board
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
3. If the board was found to be correctly inserted in
step 1, then issue the
busyout board
command.
4. Issue the
reset board
command.
5. Issue the
release busy board
command.
6. Issue the
test board long
command.
This should re-establish the linkage between the internal
ID and the port.
ID and the port.
Table 10-474.
TEST #1214 One-Way Span Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page