Maintenance Object Repair Procedures 
Page 10-1641
VC-DSPPT 
10
Notes:
a. This port has been busied out by the 
busyout port PCSSpp
 command.
b. The VC DSP Port NPE Crosstalk Test(#1103) failed.
c. The VC DSP Port Local TDM Loopback Test(#1104) failed. Run the Long 
Test Sequence.
d. A critical hardware failure has been detected on the circuit pack. Reset 
the port by the 
busyout port PCSSpp
 and 
reset port PCSSpp
 
commands. If the VC Reset DSP Test (#1106) passes, then the on-board 
circuitry is healthy. Retire the alarm with the 
test port PCSSpp long clear
 
command.
e. The VC DSP port reported loss of framing on the Service Channel between 
the VC and MMI circuit packs.
f. The VC DSP Port DSP Loopback Test (#1105) failed.
g. The DSP corresponding to this port on the VC circuit pack reported a 
firmware error. No action is required.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the DSP NPE Crosstalk Test, for example, you may 
also clear errors generated from other tests in the testing sequence.
* D = Destructive; ND = Nondestructive
VC DSP Port NPE Crosstalk Test (#1103)
This test is destructive.
The NPE controls port connectivity and gain and provides conferencing 
functions. The NPE Crosstalk test verifies that this port’s NPE channel talks on the 
selected time slot and never crosses over to time slots reserved for other 
connections. If the NPE is not working correctly, one-way and noisy connections 
may be observed. This test is part of the port’s long test sequence and takes 
approximately 20 to 30 seconds to complete. 
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND*
DSP NPE Crosstalk Test (#1103) 
X
D
TDM Loopback Test (#1104)
X
X
D
DSP Loopback Test (#1105)
X
X
D