Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1659
WAE-PORT (Wideband Access Endpoint Port)
10
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
a. The wideband access endpoint has been busied out by a
busyout
access-endpoint <extension>
command. No calls can be made to this
extension.
b. The circuit pack has been removed, or it has been insane for more than 11
minutes. To clear the error, reinsert or replace the circuit pack.
c. The Conference Circuit Test (#7) failed on this port. See Test #7 for repair
procedures.
d. The NPE Crosstalk Test (#6) failed on this port. See Test #6 for repair
procedures.
e. There was a failure of the TN464C UDS1 Interface circuit pack. See
UDS1-BD Maintenance documentation for details.
f. The Port Audit and Update Test (#36) failed due to an internal system
error. Enter the
status access-endpoint <extension>
command and
verify the status of the port. If the wideband access endpoint is
out-of-service, enter the
out-of-service, enter the
release access-endpoint <extension>
command to put it back to in-service. Retry the test command. If the test
continues to fail, escalate the problem.
continues to fail, escalate the problem.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
test description and follow the recommended procedures.
Wideband Access Endpoint Maintenance Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test access-endpoint
<extension> sh r 1
<extension> sh r 1
18 (a)
0
busyout
access-endpoint
access-endpoint
WARNING
OFF
release access-endpoint
<extension>
<extension>
130 (b)
None
WARNING
ON
test access-endpoint
<extension>
<extension>
1281 (c)
Conference Circuit
(Test #7)
(Test #7)
MINOR
ON
test access-endpoint
<extension> l r 4
<extension> l r 4
1537 (d)
NPE Crosstalk Test
(#6)
(#6)
MINOR
ON
test access-endpoint
<extension> l r 3
<extension> l r 3
1793 (e)
None
test board PCSS long
3840 (f)
Any
Port Audit and
Update (Test #36)
Update (Test #36)