Maintenance Commands and Trouble-Clearing Aids 
Page 8-50
change circuit-packs 
8
Error Messages
If there is no "test hardware-group" command currently active to be canceled, the 
following message will be displayed:
 Command aborted - no hardware-group test in progress
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
 ’login id’:’command’ has a command conflict
Output
If a "test hardware-group" command executing in the background is successfully 
canceled with the "cancel hardware-group" command, the following response 
will be displayed:
 Hardware-group command successfully canceled
If a "test hardware-group" command executing in the foreground is successfully 
canceled with a "cancel hardware-group" command from another SAT terminal, 
the following response will be displayed on the SAT terminal where the 
hardware-group command was executing:
 Hardware-group command aborted with cancel command entered from another SAT
Feature Interactions
Scheduled and Periodic Maintenance
When a "test hardware-group" is entered, all activity related to scheduled 
background maintenance, periodic background maintenance, and data audits is 
suspended for the duration of the execution of the "test hardware-group" 
command. All activity related to scheduled background maintenance, periodic 
background maintenance, and data audits will restart if the "test hardware-group" 
command is canceled.
Status Hardware-group
The state of a canceled "test hardware-group" command can be displayed by 
means of the "status hardware-group" command and the state will show up as 
’canceled’.
change circuit-packs
This command allows the user to add, change, or remove circuit packs which are 
administered.