Maintenance Commands and Trouble-Clearing Aids 
Page 8-59
change system-parameters maintenance 
8
change system-parameters 
maintenance
change system-parameters maintenance
The maintenance-related system parameters form specifies and displays 
scheduled maintenance operations and maintenance support functions.
This form activates and deactivates INADS alarm origination when performing 
repairs. To deactivate alarm origination:
1. Make a note of the current entries in the Alarm Origination and CPE Alarm 
fields so you can restore them when you are done.
2. Change the Alarm Origination to OSS Numbers field to “neither.”
3. Change the CPE Alarm Activation Level field to “none.”
4. If daily scheduled maintenance must be prevented from starting during a 
maintenance procedure, set the 
Start Time
 field to a time after the 
session will end. If daily Scheduled Maintenance is already running and 
needs to be shut off, set the 
Stop Time 
field to one minute after the 
current time.
5. Press 
Enter
 and verify that the screen displays the message:
Command successfully completed
NOTE:
For earlier releases of system software, disable Cleared Alarm 
Notification and Restart Notification before submitting the form.
NOTE:
When finished working on the switch be sure to return all fields to 
their original settings.
Examples
change system-parameters maintenance
Output
An input form displays with the following fields. Defaults for data entry fields are 
listed in parentheses.