Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
Maintenance Architecture 
Page 1-1
Maintenance Objects 
1
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
1
1
Maintenance Architecture
The maintenance subsystem is a part of the software that initializes and 
maintains the system. The software continuously monitors system health, and 
keeps a record of errors detected in the system. The maintenance subsystem 
also provides a user interface for on-demand testing.
This chapter provides a brief description of the Release 5 maintenance strategy 
and the background information on the system’s overall functions. For detailed 
descriptions of components and subsystems, refer to related topics in 
Maintenance Objects
The system is partitioned into separate entities called Maintenance Objects 
(MOs). Each MO is referred to by an upper-case, mnemonic-like name that 
serves as an abbreviation for the MO. For example, “CO-TRK” stands for “Central 
Office TRunK”. Each MO is monitored by the system and has its own 
maintenance strategy. Most MOs are individual circuit packs. Some MOs are 
hardware components that reside on part of a circuit pack. For example, the 
TDM bus Clock circuits reside on the Tone/Clock circuit pack. Other MOs, such 
as cabinet environmental sensors, represent larger subsystems or sets of 
monitors. Finally, some MOs, such as SYNChronization, represent processes or a 
combination of processes and hardware.
“Maintenance names” are recorded in the error and alarm logs. Individual copies 
of an MO are assigned an address that defines the MO’s physical location in the 
system. These locations display as the “PORT” field in the alarm and error logs 
and as output of various commands such as 
test board
busy tdm-bus
, and so 
forth.