Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-95
display alarms 
8
Error Messages
If the test-number entered is not a valid system test number, the following error 
message will be displayed:
 Test number invalid
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
 ’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
 Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
 All maintenance resources busy; try again later
Output
If the disable test-number command is successful, the following message is 
displayed:
 Command successfully completed
If the disable test-number command is unsuccessful, the following message is 
displayed:
 Error encountered, can’t complete request
Feature Interactions
None.
display alarms
This command will display an options form which allows the technician to choose 
which alarms are to be displayed. 
Synopsis
display alarms 
[ print | schedule ]