Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-163
enable suspend-alm-orig 
8
Help Messages
If you press 
Help
 after entering "enable mst", the following message displays:
 Entry is not required
Error Messages
If the command conflicts with another currently executing command, a message 
displays the login ID of the conflicting user and the conflicting command.
 ’login id’:’command’ has a command conflict
Output
After you enter the command the following message displays:
 Command successfully completed
Feature Interactions
None.
enable suspend-alm-orig
This command suspends Alarm Origination for alarms generated from a 
specified hardware component over a time-out duration.
Synopsis
enable suspend-alm-orig (board or port location) [off-board-only] 
expires-in-hrs(1-72).
Examples
enable suspend-alm-orig 1C03 expires-in-hrs 3
enable suspend-alm-orig 1E0701 expires-in-hrs 72
enable suspend-alm-orig 1E07 off-board-only expires-in-hrs 24
Description
This command enables Suspend Alarm Origination for a board (which also 
includes all ports and endpoints on the board) or for a port (which includes all 
endpoints on the port), and either for both on- and off-board alarms or for 
off-board alarms only. Many control circuit packs do not have a board location, 
so this command cannot support all circuit packs.