Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-265
monitor trunk 
8
Output
For the following output example, the command that was entered is "monitor 
trunk 78/1".
Feature Interactions
None.
Trunk 
Group/Member
The trunk group number and group member number. Valid 
identifiers are 1-99/1-99.
Port
The port location (cabinet-carrier-slot-circuit) of the trunk.
Signaling Group 
ID
If the trunk is of type ISDN, then this field contains the number of the 
ISDN Signaling Group to which this group belongs. Otherwise, this 
field is blank.
Connected 
Ports
Port locations (cabinet-carrier-slot-circuit) connected to the trunk.
Service State
Whether the trunk is in service or out of service. One of the following 
states is displayed: in-service/active, in-service/idle, out-of-service, 
out-of-service-NE (Near End), out-of-service-FE (Far End), 
maint-NE/active, maint-FE/active, maint-NE/idle, maint-FE/idle, 
pending-in-service, pending-maint, or disconnected. NE (Near End) 
and FE (Far End) refer to which "end" of the trunk has placed the 
facility in the state that it is in.
Maintenance 
Busy
Whether there is any maintenance testing being performed upon the 
trunk.
CA-TSC State
The state of the temporary signaling connection. A temporary 
signaling connection is a connection set up to pass call information 
over PRI signaling links.
 
monitor trunk 78/1
                              TRUNK STATUS
 Trunk Group/Member: 078/001            Service State: in-service/idle
               Port: 01C1505         Maintenance Busy? no
 Signaling Group ID:                     CA-TSC State:
    Connected Ports: