Maintenance Commands and Trouble-Clearing Aids 
Page 8-316
reset board 
8
Defaults
The carrier and repeat number default to 1.
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "reset board," the following 
message will be displayed:
Enter board location, [’repeat’ (1-100)]
Error Messages
If the format of the board location is incorrect, the following error message will be 
displayed:
Port/Board invalid
If the EPN on which the specified board is not available, the following message 
will be displayed:
EPN is not available
If a board is not inserted in the specified location, then the following message will 
be displayed:
Board not assigned
If the specified board is active, the following message will be displayed:
Illegal command for active object; 
use ’set’ to switch to standby
If a reset is attempted on an invalid board in the service slot, the following 
message is displayed:
Board invalid
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
location
A "location" represents the physical position of the port board to be 
reset and is entered as "UUcSS" where "UU" represents the cabinet 
number ( 1 - 3), "c" represents the carrier, and "SS" represents the slot 
position.
number
The "number" specifies how many times each board reset is to be 
repeated. "Number" may be any integer between 1 and 100.