Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-373
status access-endpoint 
8
Permissions
The following default logins may execute this command: system technician, cust, 
inads, init, nms, browse.
Examples
status access-endpoint 25012 
status access-endpoint 77868
status access-endpoint 66078 print
Description
The status access-endpoint command displays internal software state 
information for diagnosis. This command can help locate facilities with which an 
Access Endpoint is communicating.
Defaults
No defaults.
Parameters
Help Messages
If the user presses 
HELP
 after entering "status access-endpoint," the following 
message is displayed:
Enter assigned extension, [’print’]
Error Messages
If the format for the extension is incorrect, the following message displays:
Extension invalid
If the extension is not administered, the following message displays:
Extension not assigned
If the object associated with the specified extension is not an access endpoint, 
the following message will be displayed:
Extension assigned to object 
extension
The extension number of the access endpoint to be displayed. The 
number of digits in an extension is determined by the dial-plan.
print
This will cause the report to be printed if a printer is connected to the 
SAT.