Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-457
status health 
8
Description
The status health command displays the current system alarm summary, 
maintenance busy summary, user summary, critical system status, and cabinet 
status. This is the same page that is displayed when "monitor health" is entered, 
except with the "status health" command the output page is not updated 
periodically.
Defaults
None.
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "status health", the following 
object command word choices will be displayed:
[’print’]
Error Messages
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
Command resources busy;
 Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
Output
print
This will cause the report to be printed if a printer is linked to the SAT.
Major
The number of logged major alarms is displayed as a number ranging 
from 0 to 200. Up to 200 major alarms can be reported in the alarm log; 
therefore, this is the maximum which can be displayed.
Minor
The number of logged minor alarms is displayed as a number ranging 
from 0 to 200. Up to 200 minor alarms can be reported in the alarm log; 
therefore, this is the maximum which can be displayed.
Warning
The number of warnings logged in the alarm file is displayed as a value 
between 0 and 200, which is the maximum number of warnings 
permitted.