Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-508
status synchronization 
8
Examples
status synchronization
status synchronization print
Description
The status synchronization command displays the location of the DS1 or 
tone-clock circuit pack that is used for an on-line synchronization reference.
The synchronization subsystem provides error free digital communication 
between the switch and other PBXs, COs, or customer premise equipment. The 
subsystem is made up of system components involved in synchronization: TDM 
bus clock, DS1 trunk board, maintenance and administration software resident in 
the SPE.
Defaults
No defaults.
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "status synchronization", the 
following message will be displayed:
[’print’]
Error Messages
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
Command resources busy; 
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
print