Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-546
test analog-testcall 
8
Description
The test analog-testcall command performs facility diagnostic tests on an entire 
trunk group, an individual trunk group member, an individual trunk port or on all 
trunks on a board, depending on the options entered by the technician. The type 
of test call, the far end test line number and the various other test call related 
parameters must be administered on the trunk group form before executing the 
command. Press 
HELP.
Normally the user should only invoke the full or supervision test. The other 
options are provided primarily for testing when setting up an ATMS schedule.
Defaults
The default for the command is full with the repeat of 1.
Parameters
group number
The group number is an administered number associated with each 
trunk group.
member number
The member number is an administered number identifying a 
particular trunk within a trunk group. If a group number is entered, 
and no member number is given, then all trunks in the group will be 
tested.
location
A "location" represents the physical position of the board or port to be 
tested and is entered as "UUcSSpp" where "UU" represents the 
cabinet number, "c" represents the carrier, "SS" represents the slot 
position, and "pp" represents the circuit. A cabinet number (1 - 3) 
may be entered. The "pp" should be omitted for a board location.
full
This will execute the most comprehensive test call available using the 
administered test set type.
supervision
This will cause the system to execute a supervision only test call. It 
will take about 10 seconds and will only confirm the presence of the 
test set at the far end.
no-selftest
This will execute the "full" test, but will skip any self test sequences. 
This saves about 20 seconds on the type 105 transmission test and 
will not have any effect on type 100 transmission tests or on type 102 
transmission tests.
no-return-loss
This will execute the "full" test, but will skip any return loss sequences. 
This saves about 20 seconds on the type 105 transmission test and 
will not have any effect on type 100 transmission tests or type 102 
transmission tests.