Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-565
test data-module 
8
Synopsis
test data-module extension 
[ short | long ][ repeat number | clear ] schedule
Permissions
The following default logins may execute this command: system technician, 
inads, cust, init, nms.
Examples
test data-module 30000 l
test data-module 30000
test data-module 32000 sh r 2
test data-module 33000 l r 25
test data-module 33000 l r 25 schedule
test data-module 30000 c
Description
The test data-module command performs hardware diagnostic tests on a data 
module or a data channel. Test results are determined by the interface to the 
digital switch-data line port, digital line port, or network control data channel.
Defaults
The default for the command is short with the repeat of 1.