DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-579
test eda-external-device-alrm 
8
Output
For the following output example the command that was entered was "
test 
external-device-alarm all
":
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
Field definitions:
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance object 
that is being tested.
Maintenance 
Name
The type of maintenance object that is being tested.
Alt. Name
The alternate means of identifying the maintenance object. This is an 
administered more descriptive name of the external device alarm
Test No
The actual test that is being executed.
Result
The result of the individual test -"PASS", "ABORT", "FAIL",
"NO BOARD", "DISABLED", "EXTRA BD".
Error Code
A system-generated number that tells why the release failed or aborted. 
A detailed list of the codes according to "Test No." is provided for each 
MO.
test eda-external-device-alrm all
 
                             TEST RESULTS
 
  Port      Maintenance Name  Alt. Name Test No. Result            Error Code
 
  03major   EXT-DEV           CMS1      120      PASS
  03A2102   EXT_DEV           CMS2      120      FAIL
  01major   EXT-DEV           UPS1      120      PASS
  01minor   EXT-DEV           UPS1      120      PASS
  01c1201   EXT-DEV           UPS1      120      PASS
  03A2101   EXT_DEV           CC temp   120      PASS
  01c1202   EXT-DEV           Audix1    120      PASS
  03minor   EXT-DEV           Audix2    120      FAIL
  04major   EXT-DEV           unknown   120      FAIL
 
 
 
 
 
 
Command successfully completed