DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-599
test interface 
8
Help Messages
If the system technician presses 
HELP
 after entering "test interface" the following 
message will be displayed:
Enter [cabinet(1)];carrier(A-B), pos(1-2),
[’long’ or ’short’], [’repeat’ (1-100)
or ’clear’], [’schedule’]
Error Messages
If the specified carrier is not the active PE, the following message will be 
displayed:
Command must be executed from active SPE
If the technician-entered cabinet and carrier is invalid for a PPN, the following 
message will be displayed:
Invalid port-network specified
If the technician-entered carrier is not a valid carrier, the following message will 
be displayed:
Invalid carrier specified
repeat number
The "number" specifies how many times each test in the sequence is to 
be repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the 
alarm (if one exists against the maintenance object) is cleared or a 
single test in the sequence fails. If no alarms are registered against the 
maintenance object then the test sequence will be exercised only 
once. The long clear option forces a clear of all alarms if no errors are 
encountered during testing. The short clear option only clears alarms 
pertinent to tests in the short sequence
!
WARNING:
Since the "clear long" options clear all counters if tests pass, it is 
possible for firmware counters to be cleared even when a 
problem exists. In some cases customer service might degrade 
since calls may be routed over defective equipment.
schedule
When the "schedule" option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed in 
the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [1] for more details.