Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-604
test isdn-testcall 
8
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
For the following output example the command entered was "test isdn-testcall 
80/1".
Feature Interactions
Additional data is available after running the test. See the status isdn-testcall 
command for details on how to access the additional data.
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being tested.
Maintenance Name
The type of maintenance object that is being tested.
Alt. Name
The alternate means of identifying the maintenance object. This 
field contains the trunk object xxx/yyy, where xxx is the trunk 
group number and yyy is the member number.
Test No
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD."
Error Code
A system-generated number that tells why the test failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO [for example, see "ISDN-TRK (DS1 ISDN 
Trunk)" section error code description Test Number 258].
 
 test isdn-testcall 77/1                             SPE A
                         TEST RESULTS
   Port      Maintenance Name  Alt. Name Test No. Result       Error Code
   01B1501   ISDN-TRK          077/001   258      PASS
 Command Successfully Completed