Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-631
test packet-control 
8
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
Output
For the following output example, the command test packet-control 1B long was 
entered. Note that carrier B is the active carrier in these example outputs.
Port
This field represents the Cabinet-Carrier in which the 
Packet-Control resides.
Maintenance Name
The type of maintenance object that is being busied out.
Alt. Name
This field is not used in this output display.
Test No.
This field lists the test run on the packet-control.
Result
An indicator as to whether the object was successfully busied out 
("PASS", "FAIL", "ABORT", "NO BOARD", "DISABLED", "EXTRA 
BD").
Error Code
A system-generated number that tells why the release failed or 
aborted. A detailed list of the coeds according to "Test No." is 
provided for each MO.
 
 test packet-control 1B l
 
                               TEST RESULTS
 
  Port    Maintenance Name  Alt. Name Test No.  Result      Error Code
 
  01B     PKT-CTRL                     583      PASS
  01B     PKT-CTRL                     584      PASS
  01B     PKT-CTRL                     585      PASS
 Command successfully completed