Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-638
test pms-link 
8
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "test pms-link" the following 
message will be displayed:
Enter [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the link is not administered, the following error message will be displayed:
Link not administered or not enabled
If no tests can be found for the link, the following message will be displayed:
No tests for this MO
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
Command resources busy;
short
This will cause the command to execute a series of nondestructive 
diagnostic tests.
long
This executes a more comprehensive and longer version of the diagnostic 
tests. This may involve both destructive and nondestructive tests.
repeat 
number
The "number" specifies how many times each test in the sequence is to be 
repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the 
alarm (if one exists against the maintenance object) is cleared or a single 
test in the sequence fails. If no alarms are registered against the 
maintenance object then the test sequence will be exercised only once. 
The long clear option forces a clear of all alarms if no errors are 
encountered during testing. The short clear option only clears alarms 
pertinent to tests in the short sequence.
schedule
When the "schedule" option is specified, the command is validated and 
then a scheduling form is displayed to allow the technician to schedule 
execution of the command. The command is then placed in the command 
queue and is executed at the specified time. The information displayed by 
the command is sent to the system printer instead of the screen. Refer to 
the Report Scheduler and System Printer feature specification [1] for more 
details.