Maintenance Commands and Trouble-Clearing Aids 
Page 8-656
test signaling-group 
8
If the specified group identifier is not administered, the following message is 
displayed:
No signaling group assigned
If no tests can be found for the associated MO, the following message is 
displayed:
No tests for this MO
If the software data cannot be sent to the SAT, the following message is 
displayed:
Error encountered, can’t complete request
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message is displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message is displayed:
All maintenance resources busy; try again later
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
For the following output example, assume that the command "test 
signaling-group 1" was entered.
Port
The signaling group number (1-8) of the signaling group that is 
being tested.
Maintenance Name
The type of maintenance object that is being tested.
Alt. Name
Not Applicable.
Test No
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD."
Error Code
A system-generated number that tells why the test failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO [for example, see MO section on 
"ISDN-SGR (ISDN-PRI Signaling Group)"].