Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-670
test tdm 
8
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
The command that was entered was "test synchronization short".
Feature Interactions
None.
test tdm
This command tests all the time slots on a bus associated with a PPN or an EPN.
Port
Not applicable.
Maintenance Name
The maintenance object being tested is Synchronization.
Alt. Name
Not applicable.
Test No.
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD."
Error Code
A system-generated number that tells why the release failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO.
 
 test synchronization short
                             TEST RESULTS
   Port    Maintenance Name  Alt. Name Test No. Result       Error Code
           SYNC                        417      PASS
 Command Successfully Completed