Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-686
upgrade software 
8
Parameters
None.
Help Messages
If the system technician presses 
HELP
 after entering "upgrade software," the 
following message is displayed:
Entry is not required
If no card-mem is loaded into the system, the following message will be 
displayed:
Software card-mem is not inserted in the system
If a wrong card-mem is loaded into the system, the following message will be 
displayed:
Incorrect card-mem loaded; insert software card-mem
If the directory information on the software card-mem is corrupted or the 
card-mem is not formatted properly, the following message will be displayed:
Software card-mem not readable; try another card-mem
If this command is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the 
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If the checksum on the software card-mem is bad, the following message will be 
displayed:
Bad checksum on software card-mem; try another card-mem
If the software upgrade failed in the standby SPE, the following message will be 
displayed:
No response on upgrade status from standby SPE, command failed
If the software card-mem in the standby SPE is not replaced with a translation 
card-mem within 2 minutes, the following message will be displayed:
No translation card-mem inserted 
in the standby SPE, command aborted
If the flash text checksum failed after the standby upgrade, the following 
message will be displayed:
Standby SPE text checksum failed, command aborted
If the software card-mem is not inserted in the active SPE within 2 minutes after 
the prompting string: "REPLACE TRANSLATION CARD-MEM ON <active 
carrier> WITH SOFTWARE CARD-MEM," the command has to be retried again 
and the following message will be displayed:
No software card-mem inserted in active SPE; command aborted