Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-16
ADM-CONN (Administered Connection)
10
ADM-CONN (Administered
Connection)
Connection)
An Administered Connection provides an end-to-end connection between two
access endpoints or data modules. This connection is automatically established
when the administered connection is administered and is due to be active. An
error is logged when an administered connection cannot be established or when
an established administered connection fails. An alarm is logged when a
connection cannot initially be established or fails and cannot be reestablished.
An alarming strategy is supported on a per administered connection basis. An
alarm is raised for a connection when either the number of consecutive failed
attempts to establish the connection reaches the alarm threshold or it can be
determined that a failed attempt to establish was due to an administered error.
The alarm raised ("major," "minor," "warning," or "none") is specified in the "Alarm
Type" field of the Administered Connection Administration Form.
access endpoints or data modules. This connection is automatically established
when the administered connection is administered and is due to be active. An
error is logged when an administered connection cannot be established or when
an established administered connection fails. An alarm is logged when a
connection cannot initially be established or fails and cannot be reestablished.
An alarming strategy is supported on a per administered connection basis. An
alarm is raised for a connection when either the number of consecutive failed
attempts to establish the connection reaches the alarm threshold or it can be
determined that a failed attempt to establish was due to an administered error.
The alarm raised ("major," "minor," "warning," or "none") is specified in the "Alarm
Type" field of the Administered Connection Administration Form.
Error Log Entries and Test to Clear Values
1.
Where N is an appropriate Administered Connection number determined via the PORT field from the
Alarm or Error Log.
Alarm or Error Log.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
Full Name of MO
ADM-CONN
MAJOR
status administered-connection N
Administered Connection
ADM-CONN
MINOR
status administered-connection N
Administered Connection
ADM-CONN
WARNING
status administered-connection N
Administered Connection
Table 10-8.
Administered Connection Error Log Entries
Error Type
Aux Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear
Value
0 (a)(b)(c)(k)
Any
None
Any
OFF
None
1 (a)(b)(c)(d)(e)
Any
None
Any
OFF
None
2 (a)(b)(c)(f)
Any
None
Any
OFF
None
6 (a)(b)(c)(g)
Any
None
Any
OFF
None
16 (a)(b)(c)(k)
Any
None
Any
OFF
None
17 (a)(c)(h)
Any
None
Any
OFF
None
18 (a)(b)(c)(i)
Any
None
Any
OFF
None
Continued on next page