Maintenance Object Repair Procedures 
Page 10-35
ADX16D-P (16-Port AUDIX Digital Port) 
10
Voice and Control Channel Local Loop Test (#13)
This test checks the information and control channels between the Switch 
Processing Element (SPE) and the DEFINITY AUDIX port circuit. The SPE sends 
a message to loop around both the information and control channels for the port. 
First, the primary information (voice) channel loop back test is run. 
While the primary information channel is still looped around, the Control Channel 
Loop Around Test is performed. The Loop Around Test for the secondary 
information (data) channel is then performed. This test is the same as the primary 
information channel loop around test.
Next, a Conference Test is implemented for the primary information channel. This 
test is the same as Conference Test #6.
Only one value (Pass, Fail, or Abort) is generated as a result of the four tests run. 
If any test fails or aborts, the sequence is stopped.
Table 10-14.
TEST #13 Voice and Control Channel Local Loop Test 
Error 
Code
Test 
Result
Description/Recommendation
ABORT
Internal System Error (a)
1000
ABORT
System resources required to run this test are not available. The port may 
be in use. Use the 
display port PCSSpp
 command to determine the voice 
port extension of the port. Use the 
status station
 command to determine 
the service state of the port. If the port is in use, it is unavailable for certain 
tests. Refer to “Status” commands in Chapter 8, "Maintenance Commands 
and Trouble-Clearing Aids" for explanations of all possible states. Wait 
until the port is idle before retesting, then try (a).
1001
ABORT
System resources required to run this test are not available; try (a).
1002
ABORT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions, or it may have time slots that are 
out-of-service due to TDM-BUS errors. Refer to “TDM-BUS” to diagnose 
TDM-BUS errors.
1. If the system has no TDM-BUS errors and if it is not handling heavy 
traffic, try (a).
1003
ABORT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of tone detectors present, or some tone 
detectors may be out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors. Try (a).
Continued on next page