Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-38
ADX16A-PT (AUDIX Analog Line/Control Link) 
10
Error Log Entries and Test to Clear Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates 
that no terminal equipment was present when ringing was attempted. 
Execute the short 
test port PCSSpp
 command.
b. The circuit pack has been logically administered but not physically 
installed. The alarm will be cleared when the circuit pack is installed.
c. The circuit pack has been removed or has been insane for more than 11 
minutes. To clear the error, reseat or replace the circuit pack.
d. This is an in-line error and can only be resolved over time. This error 
indicates that ringing voltage is absent. If only one analog circuit pack in 
the system has this problem, then replace the circuit pack. If only analog 
circuit packs on a particular carrier have this error, then the ringing 
generator may not be connected to this carrier. If analog circuit packs on 
many carriers have this error, check the ringing generator.
e. AUDIX is not available to the switch. Check the AUDIX system, referring to 
DEFINITY AUDIX System Maintenance
, 585-300-110.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options
 command. 
Table 10-15.
DEFINITY AUDIX Analog Line/Control Link Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1(a)
40977
None
18
0
busyout station 
<
extension>
WRN
ON
release station 
extension
23(b)
0
None
WRN
OFF
130(c)
None
WRN
ON
test port PCSSpp sh
257(d)
40973
None
513(e)
Any
None
1025(f)
Loop Around Test 
(#161)
MIN/ 
WRN
2
ON
test port 
PCSSpp l r 2
1281
Conference Test (#7)
MIN/ 
WRN
2
ON
test port 
PCSSpp l r 2
1537
NPE Crosstalk Test (#6)
MIN/ 
WRN
2
ON
test port 
PCSSpp l r 2