Maintenance Object Repair Procedures 
Page 10-47
ANL-16-L (16-Port Neon Analog Line) 
10
40977
indicates that no terminal equipment was connected when 
ringing was attempted. Run the short Test via the
 test port 
PCSSpp
 command, and follow the procedure for the results of Test 
#48.
b. This is a software audit error that does not indicate any hardware 
malfunction. Run Short Test Sequence and investigate associated errors 
(if any).
c. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11 minutes. To clear the error, reinsert or 
replace the circuit pack.
d. This is an in-line error and can only be resolved over time. This error 
indicates that ringing voltage is absent. If only one Analog circuit pack in 
the system has this problem, then replace the circuit pack. If only Analog 
circuit packs on a particular carrier have this error, then the ringing 
generator may not be connected to this carrier. If Analog circuit packs on 
many carriers have this error, then it is probably a problem with the ringing 
generator.
e. Test #48 may cause some terminal equipment to ring briefly during daily 
maintenance. If this ringing is disturbing the customer or the terminal 
equipment, it should be disabled using the 
change station <extension>
 
command. However, on some releases of the software, this action 
disables Tests #6, #7, #161, and #35 as well as Test #48.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the following table when 
inspecting errors in the system. By clearing error codes associated with the 
Battery Feed Test,
 for example, you may also clear errors generated from other 
tests in the testing sequence.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Battery Feed Test (#35)
X
X
ND
Station Present Test (#48)
X
X
ND
Loop Around Test (#161)
X
ND
Conference Test (#7)
X
ND
NPE Crosstalk Test (#6)
X
ND
Station Status and Translation Audits and Updates Test (#36)
X
X
ND