Table 2.1    Configuration of the Power Supply 
Jumper 
Connector 
Power 
Supply 
Name Condition 
Description 
Shorted 
between 1–2 
Default 
Power supply from VCCE (CN2) 
CN1 VCC-BUS J3 
Shorted 
between 2–3 
 
Power supply from VCC-BUS (CN1)
CN2 VCCE — 
— 
—  VCCE 
power 
supply 
— VCCER 
J4 
Shorted  
between 1–2 
Default  
(Note1) 
Power supply from VCCE 
— AVCC0 
J5 
Shorted 
between 1–2 
Default 
Power supply from VCCE 
— VREF0 
J6 
Shorted 
between 1–2 
Default 
Power supply from AVCC0 
— VDDE 
J7 
Shorted 
between 1–2 
Default 
Power supply from VCCE 
Note1: Case of opened between 1-2, power supply from VCCE is stopped. 
Case that 3.3 V power supply is inputted to VCCER by using 3.3 V generated circuit on board, the following items 
should be prepared by the user.   
- U3: regulator 
- D1,D2: diode 
- C4,C5: capacitor 
Note:    The J3, J4, J5, J6 and J7 jumpers are shorted by pattern wiring on the reverse side of printed Circuit board.   