Dialogic M7324 Manual Do Utilizador

Página de 178
Dialogic
®
 PBX Integration Board User’s Guide  
value of eight [0x08] indicates ON), while the green light has six possible 
values. The status of the indicators is obtained by bitwise-ANDing the 
returned value from the green light with the value from the red light (green 
light value + red light value). In other words, the value for a line indicator in 
use with a call (after ANDing with 0x0f, all the values shown below in the 
least significant byte value) would be nine--0x08 (for red light on) + 0x01 (for 
green light on). The status conditions for each byte (least significant) of the 
green light are defined as indicated in 
Table 2.  Avaya 7434 and 8434 LED Indicator States 
State Value 
(Hex) 
off 
0x00 
on 
0x01 
ringing 
0x02 
hold 
0x03 
error 
0x04 
unknown 
0x05 
Reading LED Indicators 
The Dialogic
® 
PBX Integration Board can determine the state of its LED 
indicators by using the d42_indicators( ) function to retrieve the LED 
indicators data. This function places the Line Indicator data (34 bytes) in an 
application buffer. Bytes 1-34 contain the indicator status for Memory Keys 
00-33, respectively (see 
Table 3.  Avaya 7434 and 8434  
Direct Key Dialing Strings for Feature Keys 
Byte 
Key Description 
Dial String  
Feature Button 00 
<ESC>KA 
Feature Button 01 
<ESC>KB 
Feature Button 02 
<ESC>KC 
42