4.6.  Watch Mode 
This section explains watch mode. 
 Main Clock Supervisor 
The main clock supervisor function is not influenced from the transition to the watch mode.   
When the main clock stops, the change dividing and reset are issued to the CR oscillation clock when the 
main clock is connected with the permission of the main clock supervisor function and RTC. 
The watch mode is made clear, and RTC is initialized.   
The RTC clock stops only because it does not detect it even if the main clock stops when the main clock is 
connected with the prohibition of the main clock supervisor function and RTC.   
 Sub Clock Supervisor 
The sub clock supervisor function is not influenced from the transition to the watch mode. 
When a sub clock is connected with the permission of the sub clock supervisor function and RTC, reset is 
not issued though it cuts in the CR oscillation clock when a sub clock stops.   
The RTC clock stops only because it does not detect it even if the sub clock stops when the sub clock is 
connected with the prohibition of the sub clock supervisor function and RTC. 