CHAPTER 40: MULTI-FUNCTION SERIAL INTERFACE 
 
 
5. Operation of UART 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : MULTI-FUNCTION SERIAL INTERFACE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
163 
Figure 5-16 Synchronous Transmission Operation (STMCR="10", TBYTE0="2") 
10
0
1
・・・
9
10
1
0
STMR
STMCR
TINT
Timer 
activation
1
st
 Byte
・・・ 10
1
0
2
nd
 Byte
・・・ 10
1
0
TDRE
Transmission 
data
Output transmission data when there is a 
match between STMR and STMCR
No data transmission because there is 
no data (TDRE=0)
2
3
4
3
rd
 Byte
L
TDR RW
TBI
2
4
th
 Byte
Output transmission data when there is a 
match between STMR and STMCR
Transmissions 
counter*A
2
1
0
2
1
0
2
TBYTE0
2
Load
Load
*A:Internal counter to be count transmission bytes
 
If the synchronous transmission is enabled (SACSR:TSYNE="1") and the serial timer register (STMR) 
matches the serial timer comparison register (STMCR), the transmission will not start under the following 
conditions. 
  When transmission is disabled (SCR:TXE="0") 
  When there is no valid data in the transmission data register (SSR:TDRE="1") 
If the transmission data register (TDR) has valid transmission data (SSR:TDRE="0") after the data 
transmission is completed as many as the number of data set to TBYTE, then, the transmission data will not 
be sent until the serial timer register (STMR) matches the serial timer comparison register (STMCR). 
However, if the synchronous transmission is enabled (SACSR:TSYNE="1") and the serial timer register 
(STMR) matches the serial timer comparison register (STMCR) under the following conditions, the 
transmission will not be stopped and the next transmission will be started after sending as much data as 
TBYTE0. 
  Transmission operation in progress (SSR:TBI="0") 
Notes: 
  If the synchronous transmission is enabled (SACSR:TSYNE="1"), the external trigger is enabled 
(SACSR:TRGE="1"), and the serial timer comparison register (STMCR) is set to (0000)H, it will not 
operate the synchronous transmission but the transmission by external trigger. 
  When the transmit data register (TDR) has no valid transmission data (SSR:TDRE="1") before sending 
the data frame of TBYTE setting, the following operation will be performed. 
  Transmission operation will be stopped until transmission data is written to the transmission data 
register (TDR). Transmission operation will be restarted when transmission data is written to the 
transmission data register (TDR). 
 
MB91520 Series
MN705-00010-1v0-E
1476