AMCC 9590SE-4ME Manual Do Utilizador

Página de 93
Controller Object Commands
www.3ware.com 
27
Typical output looks like: 
//localhost> /c0 show
Unit   UnitType  Status    %Cmpl   Stripe  Size(GB) Cache  AVerify  IgnECC
--------------------------------------------------------------------------
u0     RAID-1      OK        -       -       149.05   ON     OFF      OFF
u1     RAID-5      OK        -       64k     298.22   ON     OFF      OFF
u2     SPARE       OK        -       -       149.05   ON     OFF      -
Port   Status        Unit   Size        Blocks        Serial
---------------------------------------------------------------
p0     OK            u0     149.05 GB   312581808     3JS0TF14      
p1     OK            u0     149.05 GB   312581808     3JS0TETZ      
p2     OK            u1     149.05 GB   312581808     3JS0VG85      
p3     OK            u1     149.05 GB   312581808     3JS0VGCY      
p4     OK            u1     149.05 GB   312581808     3JS0VGGQ      
p5     OK            u2     149.05 GB   312581808     3JS0VH1P      
p6     OK            -      149.05 GB   312581808     3JS0TF0P      
p7     OK            -      149.05 GB   312581808     3JS0VF43      
p8     OK            -      149.05 GB   312581808     3JS0VG8D      
p9     NOT-PRESENT   -      -           -             -
p10    NOT-PRESENT   -      -           -             -
p11    NOT-PRESENT   -      -           -             -
Name  OnlineState  BBUReady  Status    Volt     Temp     Hours  LastCapTest
---------------------------------------------------------------------------
bbu   On           Yes       OK        OK       OK       241    22-Jun-2004
/c
x
 show 
attribute
 [
attribute
 ...]
This command shows the current setting of the specified attributes on the 
specified controller. One or many attributes can be specified. Specifying an 
invalid attribute will terminate the loop. Possible attributes are: achip, 
allunitstatus, autocarve (9000 series), autorebuild (9550SX and 9590SE only), 
bios, carvesize (9000 series), driver, drivestatus, exportjbod (9000 series), 
firmware, memory, model, monitor, numdrives, numports, numunits, ctlbus 
(9550SX and 9590SE only),  ondegrade (9500S), pcb, pchip, qpolicy, serial, 
spinup (9000 series), stagger (9000 series), and unitstatus. 
Example:
 To see the driver and firmware installed on controller 0, enter the 
following:
//localhost> /c0 show driver firmware
/c0 Driver Version = 2.x
/c0 Firmware Version  = FE9X 2.x
Where x=actual version