Symmetricom 1100 Manual Do Utilizador

Página de 224
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
176  TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Using Alarm Codes to Troubleshoot
 lists the alarm codes generated by the TimeProvider. Unless specified, 
each alarm has a default Error Delay of Immediate, and you cannot edit the Error 
Delay. 
INPTRR
Tip/ring reversal on CC input
Tip/ring connection correct on CC input
EXDSC
Excessive discontinuity fault
Excessive discontinuity cleared
MTIE
MTIE exceeded threshold
MTIE within threshold
OUT[g] Codes
OUTFAIL
Output fault 
Output fault cleared
SYNTHEOR
Output generator exceeds pull-in range
Output generator within pull-in range
SYNTHFAIL
Output generator failed
Output generator restored
E422[g] Codes
E422EQPT
EIA-422 Output module is unequipped
EIA-422 Output module is equipped
E422FAULT
EIA-422 Output module has a fault
EIA-422 Output module fault cleared
RTMg[-p] Codes
RTMEQPT
Retimer module is unequipped
Retimer module is equipped
S1LOS
Side 1 LOS fault
Side 1 LOS fault cleared
S2LOS
Side 2 LOS fault
Side 2 LOS fault cleared
EXSLIP
Slip rate threshold exceeded
Slip rate within threshold
RTMFAULT
Retimer module has a fault
Retimer module fault cleared
Table 6-7.  Alarm Codes 
Event ID
Description
AID
TYPE
Service 
Affecting
Alarm Level
SSU 
Mode 
PRR 
Mode 
SUB 
Mode 
AID = SYS
COMPAT
System components (hardware 
or software) are incompatible.
EQPT
NSA
MJ
MJ
MJ
Table 6-6.  Set and Clear Conditions for Alarms (Continued)
Alarm ID
Set Alarm Conditional Description
Clear Alarm Conditional Description