Lincoln Electric SVM159-A Manual Do Utilizador

Página de 134
POWER WAVE 355/405
A-2
INSTALLATION   
A-2
TECHNICAL SPECIFICATIONS - 
POWER WAVE 355
INPUT AC VOLTAGE & DC OUTPUT
Product
Ordering
Input AC
Rated DC Output           Output
Weight               Dimensions
Name
Information
Voltage
Amps/Volts/Duty Cycle
Range
with Cord
HxWxD
(continuous)
* Overall Length Including Handle, 21.6” (549mm) without handle.
Voltage
200
208
230
380
400
415
460
575
200
208
230
380
400
415
460
575
Phases
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
300Amps @
32Volts(100%)
Not
Recommended
76
69
Not
Recommended
Not
Recommended
41
36
31
41
39
36
23
22
22
19
16
350Amps @
34Volts(60%)
Not
Recommended
94
85
Not
Recommended
Not
Recommended
64
42
37
50
50
42
28
27
26
23
18
Line Cord
AWG
2
4
---
6
8
8
6
6
8
8
8
8
8
8
Fuse size
---
125A
125A
---
---
80A
70A
50A
80A
80A
70A
50A
50A
50A
50A
35A
POWER WAVE 355 INPUT CURRENT
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Output
Recommended
Note 1. Not rated is indicated by 4-x’s in the box on the rating plate.
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
Select The output cable size based upon the following chart.*
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE
100%
60%
CURRENT
300
350
LENGTH UP 200FT.(61m)
1/0
1/0
200-250 FT. (61-76m)
1/0
2/0
Notes
Note 1
Note 2
Note 2
Note 1
Note 1
Note 2
Note 2
Note 2
*
Lincoln Electric recommends using a minimum of 2/0 welding cable for pulse welding.
Power
Wave
355
K2152-1
200-208
220-240
380-415
440-480
575
60/50 HZ
350A / 34V / 60%
1 & 3 Phase
300A / 32V / 100%
1 & 3 Phase
AMPS
5-425
(81.5 lbs.)
(37.0 kg.)
14.8” x 13.3” x
27.8”*
(373 x 338 x
706*)mm
*Includes
Handles