Parameter  Description 
Packet 
Data 
STU-
III 
&C1 
Circuit 109 (CF) ON in accordance with the specified 
service.
 DCD line is High during a circuit switched call. 
 
R N/A 
&C2 
Circuit 109 (CF) ON
. DCD is always high. This line toggles 
low for 1 second when the circuit switched call is 
disconnected. 
 
R N/A 
&C3 
Circuit 109 (CF) ON
. DCD is Low. High when modem has 
successfully established a PPP Data (packet switched) call 
(only applies to IP STACK)
 
R N/A 
&C4 
Circuit 109 (CF) ON
. DCD is Low. High when modem has 
successfully established a PPP Data and opened a socket 
with remote server(packet switched) call (only applies to 
IP STACK)
 
R N/A 
&D0 
Ignore circuit 108/2 (CD). 
N/A 
[&D1] 
Enter online command state following ON-to-OFF transition 
of circuit 108/2. See service specific AT command processing 
for service state transitions. 
R N/A 
&D2 
Enter command state following On to Off transition of 
circuit 108/2. See service specific AT command 
processing for service state processing requirements. 
R N/A 
Select tone dialling. 
N/A 
N/A 
&F0 
Set to factory-defined configuration. Effect is 
implementation dependent. 
O N/A 
 
12.2.2.  Basic S registers 
The following table specifies the basic S registers to be supported for the data services. Exceptions 
to EIA/TIA-602 are indicated by square brackets. Default settings are shown in bold. 
Table 12.79  Basic S-registers 
Register  Value 
Description 
Packet 
Data 
STU-
III 
S0 
[1 to 255] 
Automatic answering. [Enable automatic 
answering after (Value: 1) x 6 seconds.] 
0: Not Answer 
N/A N/A 
S3 
13 
Carriage Return character. 
N/A 
S4 
10 
Line Feed character. 
N/A 
S5 
8 Backspace 
character. 
N/A 
S6 
2 to 10 
Pause before blind dialling. 
N/A 
N/A