Multi-Tech Systems MT5600BA-V92 Manual Do Utilizador

Página de 55
Chapter 2 – AT Commands 
Multi-Tech Systems, Inc. AT Commands Reference Guide (S000273G) 
17 
 
 
Modem Connection Commands 
 
Command: +PCW=n    Call Waiting Enable 
Values:
 
n = 0, 1, or 2 
Default:
 2 
Description:
 
Controls the action to be taken upon detection of a call waiting tone in V.92 mode. 
Values specified by this command are not modified when an AT&F command is issued. 
 
+PCW=0   Toggles V.24 Circuit 125 and collects Caller ID if enabled by +VCID
 +PCW=1 
 
Hangs 
up. 
 
+PCW=2   Ignores V.92 call waiting. 
 
+PCW=?   Displays the allowed values. 
 
+PCW?  
Displays the currrent values. 
 
 
Command:  +PIG=n    PCM Upstream Ignore 
Values:
 
n = 0 or 1 
Default:
 1 
Description:
 
Controls the use of PCM upstream during V.92 operation. PCM upstream allows faster 
upload speeds to a V.92 server. 
 +PIG=0 
 
Disables 
PCM 
upstream. 
 +PIG=1 
 
Enables 
PCM 
upstream. 
 
+PIG=?  
Displays the allowed values. 
 
+PIG?  
Displays the current values. 
 
 
Command: +PQC=n  Quick Connect Control 
Values:
  
  n = 0, 1, 2, or 3 
Default: 
  
Description:
  
  Controls the V.92 shortened Phase 1 and Phase 2 startup procedures (Quick Connect). 
 
When line conditions are stable, quick connect results in shortened connect times; 
however, significant fluctuations in line conditions from call to call can result in longer 
connect times, in which case it may be advisable to disable quick connect. 
 
+PQC=0   Enables Short Phase 1 and Short Phase 2 (Quick Connect). 
 
+PQC=1   Enables Short Phase 1. 
 
+PQC=2   Enables Short Phase 2. 
 
+PQC=3   Disables Short Phase 1 and Short Phase 2. 
 
+PQC=?   Displays the allowed values. 
 
+PQC?  
Displays the current values. 
 
 
 
Command:   +PSS 
Use Short Sequence 
Description:
 
This command causes a calling modem to force either a V.92 short or full startup 
sequence as defined by the +PQC command on the next and subsequent connections. 
 
Syntax: +PSS=<value> 
Values:
  
<value>  Decimal number corresponding to the selected sequence. 
0   The modems decide whether or not to use the short startup procedures. 
The short startup procedures can only be used if enabled by the +PQC 
command. Default 
1   Reserved. 
2   Forces the use of the full startup procedures on the next and subsequent 
connections independent of the setting of the +PQC command. 
Result Codes:
 
OK 0 - 2 in V.92 Mode (+MS=V.92) 
 
ERROR Otherwise 
Report Commands:
 
+PSS?  Reports selected values. 
 
+PSS=? Reports supported range of parameter values.