Timers
16-Bit Timer Setup Examples
Panasonic  Semiconductor  Development  Company
MN102H75K/F75K/85K/F85K LSI User Manual
110
Panasonic
To service the interrupts and calculate the signal width:
1.
Run the interrupt service routine. The routine must determine the interrupt 
group, then clear the interrupt request flag.
Ignore the flags when calculat-
ing the signal width, even when 
TM3CA is the larger value.
2.
Calculate the number of cycles the TM4IA signal stays high. Save the con-
tents of TM4CA and TM4CB to the data registers, then subtract the contents 
of TM4CA from the contents of TM4CB. Since TM4LP is set to 0, the dif-
ference will be the correct value even if TM4CA is greater than TM4CB.
Timer 4 can input a two-phase capture signal. You must select up counting. Timer 4 
does not operate in STOP mode, when B
OSC
 is off. If you use an external clock, it 
must be synchronized to B
OSC
.
TM4CA captures the count on the rising edge of TM4IA, and TM4CB captures 
the count on the rising edge of TM4IB. A timer 4 capture B interrupt occurs 
when TM4CB captures the count, and the contents of TM4CA and TM4CB are 
read during the interrupt service routine.
In the example timing chart shown in figure 4-38, x’000A’ – x’0007’ = x’0003’, 
or 3 cycles. The calculation is correct even when TM4CA is the larger value. The 
flags are ignored, so for instance, x’0003’ – x’FFFE’ = x’0005’.
Figure 4-38 Two-Phase Capture Input Timing (Timer 4)
0
0
1
2
3
4
5
6
7
0
7
0
A
8
9
A
B
C
D
E
F
10
11
12
TM4EN
TM4BC
BOSC/4
TM4CA
TM4CB
TM4IA
TM4IB
Interrupt
B