Seagate ST2000DX001 Manual Do Utilizador

Página de 42
Desktop SSHD Product Manual, Rev. B
31 
SATA Interface
4.3.1 Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following 
power up. The data is organized as a single 512-byte block of data, whose contents are shown in  on page 28. All 
reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or vary with the state 
of the drive. 
The following commands contain drive-specific features that may not be included in the SATA specification.
Table 8 Identify Device commands 
Word
Description
Value
0
Configuration information:
• Bit 15: 0 = ATA; 1 = ATAPI
• Bit 7: removable media
• Bit 6: removable controller
• Bit 0: reserved
0C5A
H
1
Number of logical cylinders
16,383
2
ATA-reserved
0000
H
3
Number of logical heads
16
4
Retired
0000
H
5
Retired
0000
H
6
Number of logical sectors per logical track: 63
003F
H
7–9
Retired
0000
H
10–19
Serial number: (20 ASCII characters, 0000
H
 = none)
ASCII
20
Retired
0000
H
21
Retired
0400
H
22
Obsolete
0000
H
23–26
Firmware revision
(8 ASCII character string, padded with blanks to end of 
string)
x.xx
27–46
Drive model number:
(40 ASCII characters, padded with blanks to end of string)
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple 
and Write multiple (16)
8010
H
48
Reserved
0000
H
49
Standard Standby timer, IORDY supported and may be 
disabled
2F00
H
50
ATA-reserved
0000
H
51
PIO data-transfer cycle  timing mode
0200
H
52
Retired
0200
H
53
Words 54–58, 64–70 and 88 are valid
0007
H
54
Number of current logical  cylinders 
xxxx
H
55
Number of current logical heads 
xxxx
H
56
Number of current logical sectors per logical track
xxxx
H
57–58
Current capacity in sectors
xxxx
H