Advantech MIC-3368 Manual Do Utilizador

Página de 50
 
MIC-3368 Series User Manual -- Page  31
A.1 Programming the Watchdog Timer 
To program the watchdog timer, you must write a program which writes a value to 
I/O port address 443 (hex). This output value represents time interval. The value 
range is from 01 (hex) to FF (hex), and the related time interval is 1 sec. to 255 sec. 
Data Time Interval 
01 1 sec. 
02 2 sec. 
03 3 sec. 
04 4 sec. 
•• 
•• 
•• 
3F 63 sec. 
 
After data entry, your program must refresh the watchdog timer by rewriting the 
I/O port 443 and 043 (hex) while simultaneously setting it. When you want to 
disable the watchdog timer, your program should read I/O port 043 (hex). The 
following example shows how you might program the watchdog timer in BASIC: 
10 REM Watchdog timer example program 
20 OUT &H443, data REM Start and restart the watchdog 
30 GOSUB 1000 REM Your application task #1, 
40 OUT &H443, data REM Reset the timer 
50 GOSUB 2000 REM Your application task #2, 
60 OUT &H443, data REM Reset the timer 
70 X=INP (&H043) REM, Disable the watchdog timer 
80 END 
1000 REM Subroutine #1, your application task 
•• 
•• 
•• 
1070 RETURN 
2000 REM Subroutine #2, your application task 
•• 
•• 
•• 
2090 RETURN.