Cisco Systems uBR-MC28U Folheto

Página de 2
Step 3
Connect the US cables to the US ports on 
the card (US0–US7). All US ports are light 
blue.
Figure 3
Inserting an Attenuator
5  
Removing the Card
To prevent the alarms from activating, 
administratively shut down the card using the 
shutdown command in interface configuration 
mode before removing it from the chassis. 
Step 1
Make sure that you are properly 
grounded.
Step 2
Disconnect all the cables from the cable 
interface line card.
Step 3
Unscrew the captive installation screws on 
the faceplate. 
Figure 4
Removing the Card from the Chassis
Step 4
Grasp the handle and carefully pull the 
card out of its slot (see Figure 4). 
+42 dBmV
US2
US4
US5
US6
US7
ENABLED
DS0-IF
DS1-IF
uBR - MC28X
US1
US0
US3 
88993
Upconverter
Attenuator
Cable
Connector
88982
U
S
0
U
S
1
U
S
2
U
S
3
U
S
4
U
S
5
U
S
6
U
S
7
E
NA
B
LE
D
DS0-RF
DS1-RF
uBR - MC28U
Caution
Always handle the card by the carrier 
edges and handle; never touch the 
cable interface line card’s components 
or connector pins. For proper cooling 
and airflow, always install a line card 
cover in an empty line card slot.
Step 5
Place the card on an antistatic surface with 
its components facing upward.
Note
If the card is being returned to the factory, 
immediately place it in a static shielding 
bag and proper packaging for protection.
6  
Troubleshooting
1.
Make sure that the card is securely seated in 
the chassis.
If the captive screws do not tighten all the way, 
the card is not properly seated in the chassis or 
backplane. Carefully pull the card halfway out 
of the slot, reinsert it, and tighten the captive 
installation screws. 
Caution
A partially seated line card can cause 
the router to reboot. 
2.
Are all enabled LEDs on? If yes, the system is 
operational. 
If no, check the following possibilities:
a.
If the card has been enabled and 
configured for operations, the enabled 
LED remains on. 
b.
If a port is enabled but its enabled LED is 
still off, check if the card has pulled away 
from the router. Reseat the card in its slot. 
(Do not have to turn off the system power 
to do this.} After the system reinitializes 
the interfaces, the enabled LED on the 
card should come on.
3.
If the enabled LED remains off after the above 
checks, it is likely that the system has detected 
a processor hardware failure. Go to the Cisco 
TAC website 
for 
further information and help. 
Figure 5
LEDs
7  
Technical Specifications
Table 1
LEDs/Status
LED/Status
Description
ENABLED—green
ENABLED—off
Card operating normally
Card not enabled
US—green
US—off
Upstream enabled
Upstream not enabled
DS—green
DS—off
Downstream enabled
Downstream not enabled
Table 2
Technical Specifications
Description
Order Num/ Specifications
Cisco uBR-MC28U,
with upconverter
Cisco uBR-MC28X,
without upconverter
Cisco uBR-E-28U, 
with upconverter
UBR-MC28U, 
UBR-MC28U=
UBR-MC28X, 
UBR-MC28X=
UBR-E-28U
UBR-E-28U=
Blank covers
UBR-MC-COVER=
Weight—MC28U/E-
28U
Weight—MC28X
6 lbs (2.72 kg)
4.75 lbs (2.15 kg)
Power consumption
MC28U/E-28U
MC28X
80 Watts (273 BTU/h)
50 Watts (170.6 BTU/h)
88985
US2
US4
US5
US6
US7
ENABLED
DS
0-R
F
DS
1-R
F
uBR - MC28U
US1
US0
US3 
Downstream
LEDs
DS0-DS1
Upstream
LEDs
US0-US7
Enabled
LED
8  
Related Documentation
Cisco.com
:
Cisco uBR7200 Series Universal Broadband 
Routers
For the 1–year warranty information, visit the 
following URL:
Output—MC28U/E-
28U
Output—MC28X
+50 to 61 dBmV at RF
+42 dBmV at IF (+/-2 dB)
Modulation
Upstream (US0–US7) QPSK 8–, 16–, 32–, 
64–QAM
Downstream 
(DS0–DS1)
64–QAM, 256–QAM
RF output power range—50 to 61 dBmV
Frequency range
Upstream
Downstream
5–65 MHz
70–860 MHz
The Cisco uBR-MC28U/X/E-28U line card is 
compatible with most cable systems worldwide, 
including but not limited to—Asia Pacific, 
Europe, and the Americas. See Cisco IOS release 
notes for more information.
Table 2
Technical Specifications (continued)
Description
Order Num/ Specifications